DATA CENTER LV SWITCHBOARD & POWER DISTRIBUTION SOLUTIONS

Panel Elektro designs and manufactures low-voltage switchboards, Power Control Centers (PCC) and Motor Control Centers (MCC) for data center applications. Solutions based on the flexibility of the Logstrup Modular System are engineered in accordance with IEC 61439-1/2 requirements. The modular switchboard architecture supports internal separation up to Form 4b where specified and provisions for future capacity expansion.

KEY TECHNICAL CAPABILITIES & INTEGRATION

A/B Distribution

Redundant Power Architecture

PFlex modular low-voltage switchboards can be configured for redundant A/B distribution concepts and maintainable power paths according to the project electrical architecture.

PCC / MCC

Mechanical Infrastructure Control

Power Control Centers and Motor Control Centers support power distribution and motor control for cooling equipment, ventilation, pumps, chillers and other mechanical infrastructure.

Monitoring / SCADA

Automation & Interface Panels

Automation and SCADA panels support monitoring, control and interface functions for integration with central facility monitoring and automation systems where required.

Backup / Transfer

Generator & UPS Integration

Generator synchronization panels and UPS distribution panels support coordinated backup power operation, including project-specific input, output and maintenance bypass arrangements.

POWER DISTRIBUTION ARCHITECTURE & MAINTENANCE FLEXIBILITY

Bus Coupling and Sectional Isolation

A bus coupler allows busbar sections to be separated or alternative supply paths to be used under appropriate operating scenarios. Such arrangements are evaluated against available source capacity, protection coordination, interlocking and the approved single-line diagram.

Modular Expansion and Spare Feeders

ACB or MCCB outgoing compartments can be prepared with connection provisions for future capacity expansion. Additional breakers and cable connections are installed within the switchboard's verified design limits and in accordance with safe working procedures.

Connection Flexibility and UPS Integration

The modular switchboard architecture supports top or bottom cable and busway connections. Sectional isolation, considered alongside UPS input, output and maintenance bypass arrangements, helps maintain supply to critical loads during planned maintenance.

MAIN INDUSTRIAL APPLICATION AREAS

Electrical distribution systems are a core part of operational continuity in data center facilities.

COLOCATION / CLOUD / HYPERSCALE

Data Center Power Distribution

Main and sub-distribution switchboards can be configured for high-capacity colocation, cloud and hyperscale data center electrical architectures, including modular expansion and project-specific redundancy requirements.

MODULAR / EDGE

Compact & Modular Data Center Systems

Modular low-voltage panels can be adapted to compact or distributed data center applications where space, maintainability and future expansion need to be considered together.

INFRASTRUCTURE / COOLING

Mechanical Plant Rooms

MCC solutions can support chillers, pumps, fans, ventilation and other mechanical loads within cooling infrastructure, which becomes increasingly critical as computing densities rise.

PANEL ELEKTRO · TECHNICAL DOCUMENT

DATA CENTER TECHNICAL CATALOG

Explore Panel Elektro's engineering solutions for critical power distribution and data center infrastructure in our four-page catalog.

  • Critical power distribution and low-voltage switchgear solutions
  • Modular switchboard architecture and copper busbar systems
  • Scalable, project-specific power distribution applications
PDF · 4 pages

Request a Technical Proposal for Your Data Center Project

Share your single-line diagram, load list, UPS and A/B supply architecture (if available), maintenance and isolation requirements, and technical specifications with our sales and engineering team.

1 / 4

Swipe or use the arrows to browse · Click the catalog to enlarge.

DATA CENTER TECHNICAL CATALOG

To review similar applications and our field experience, visit our Projects and References sections.

Frequently Asked Questions About Data Center Switchboards

Data center electrical infrastructures can include main low-voltage switchboards / Main Distribution Boards (MDB), Power Control Centers (PCC), Motor Control Centers (MCC), generator synchronization panels, UPS input, output and maintenance bypass panels, as well as automation and monitoring panels. Panel Elektro provides project-specific panel solutions according to the electrical architecture and operational requirements.

No. The modular switchboard architecture can be configured according to project specifications, approved component selections, protection requirements and integration needs.

Modular low-voltage switchboards can be configured for redundant A/B distribution concepts, maintainable power paths and future capacity expansion according to the project electrical architecture and operational requirements.

Yes. Where required by the project specification, the Logstrup Modular System can be configured with internal separation up to Form 4b in accordance with the applicable IEC 61439-1/2 design and verification requirements.

Yes. Generator synchronization and UPS distribution panels can be engineered as part of the overall data center electrical architecture, including project-specific input, output, maintenance bypass, monitoring and control arrangements.

A bus coupler connects or separates two busbar sections as required. If an incoming supply is unavailable or maintenance is needed, feeding the sections from another source is possible only when sufficient source capacity, protection coordination, interlocking arrangements and an approved operating scenario are in place.

A compartment reserved for a future air circuit breaker (ACB), with the required internal connection provisions prepared as specified by the project. When an additional feeder is required, the suitable breaker and cables can be installed within the switchboard's verified design limits and under safe working procedures.

Yes. Depending on the project layout and selected switchboard configuration, cable connections can be arranged from both the top and bottom within the same assembly. Busway connections also require a suitable interface and project-specific layout verification.

You can send your single-line diagrams, technical specifications and project requirements to sales@panel.com.tr.